Part 4: Replacement of MR-J3W-_B with MR-J4W2-_B
4 - 38
MR-J3W-_B MR-J4W2-_B
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PB32 Gain changing speed integral compensation
Set the speed integral compensation when the gain
changing is valid.
This parameter is made valid when the auto tuning is
invalid ([Pr. PA08]: _ _ _ 3).
33.7
PB32 Speed integral compensation after gain switching
Set the speed integral compensation when the gain
changing is enabled.
When you set a value less than 0.1 ms, the value will be
the same as [Pr. PB10].
This parameter is enabled only when you select "Manual
mode (_ _ _ 3)" of "Gain adjustment mode selection" in
[Pr. PA08].
0.0
PB33 Gain changing vibration suppression control vibration
frequency setting
This parameter cannot be used in the speed control
mode.
Set the vibration frequency for vibration suppression
control when the gain changing is valid. This parameter
is made valid when the [Pr. PB02] setting is "_ _ _ 2" and
the [Pr. PB26] setting is " _ _ _ 1".
When using the vibration suppression control gain
changing, always execute the changing after the servo
motor has stopped.
100.0 PB33 Vibration
suppression
control 1 - Vibration frequency
after gain switching
Set the vibration frequency of the vibration suppression
control 1 for when the gain switching is enabled.
When you set a value less than 0.1 Hz, the value will be
the same as [Pr. PB19].
This parameter is enabled only when the following
conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is
"Manual mode (_ _ _ 3)".
"Vibration suppression control 1 tuning mode
selection" in [Pr. PB02] is "Manual setting (_ _ _ 2)".
"Gain switching selection" in [Pr. PB26] is "Control
command from controller is enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to
switch them after the servo motor stops.
0.0
PB34 Gain changing vibration suppression control resonance
frequency setting
This parameter cannot be used in the speed control
mode.
Set the resonance frequency for vibration suppression
control when the gain changing is valid. This parameter
is made valid when the [Pr. PB02] setting is "_ _ _ 2" and
the [Pr. PB26] setting is "_ _ _ 1".
When using the vibration suppression control gain
changing, always execute the changing after the servo
motor has stopped.
100.0 PB34 Vibration
suppression
control 1 - Resonance frequency
after gain switching
Set the resonance frequency for vibration suppression
control 1 when the gain switching is enabled.
When you set a value less than 0.1 Hz, the value will be
the same as [Pr. PB20].
This parameter will be enabled only when the following
conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is
"Manual mode (_ _ _ 3)".
"Vibration suppression control 1 tuning mode
selection" in [Pr. PB02] is "Manual setting (_ _ _ 2)".
"Gain switching selection" in [Pr. PB26] is "Control
command from controller is enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to
switch them after the servo motor stops.
0.0
PB35 This parameter is not used. Do not change the value.
0.00 PB35
Vibration
suppression
control 1 - Vibration frequency
damping after gain switching
Set a damping of the vibration frequency for vibration
suppression control 1 when the gain switching is
enabled.
This parameter will be enabled only when the following
conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is
"Manual mode (_ _ _ 3)".
"Vibration suppression control 1 tuning mode
selection" in [Pr. PB02] is "Manual setting (_ _ _ 2)".
"Gain switching selection" in [Pr. PB26] is "Control
command from controller is enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to
switch them after the servo motor stops.
0.00
PB36 This parameter is not used. Do not change the value. 0.00
PB36
Vibration
suppression control 1 - Resonance frequency
damping after gain switching
Set a damping of the resonance frequency for vibration
suppression control 1 when the gain switching is
enabled.
This parameter will be enabled only when the following
conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is
"Manual mode (_ _ _ 3)".
"Vibration suppression control 1 tuning mode
selection" in [Pr. PB02] is "Manual setting (_ _ _ 2)".
"Gain switching selection" in [Pr. PB26] is "Control
command from controller is enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to
switch them after the servo motor stops.
0.00
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...