Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
2 - 51
MR-J3-_A_
MR-J4-_A_
Control
mode
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PC37 Analog speed command offset
Used to set the offset voltage of the analog speed
command (VC).
For example, if CCW rotation is provided by
switching on forward rotation start (ST1) with 0 V
applied to VC, set a negative value.
When automatic VC offset is used, the
automatically offset value is set to this parameter.
The initial value is the value provided by the
automatic VC offset function before shipment at the
VC-LG voltage of 0 V.
Depen-
ding on
servo
amplifier
PC37 Same as MR-J3
The value
differs
depending
on the
servo
amplifiers.
S
Analog speed command offset
Set the offset voltage of VC (Analog speed
command).
For example, if CCW rotation or positive direction
travel is provided by switching on ST1 (Forward
rotation start) while applying 0 V to VC, set a
negative value.
When automatic VC offset is used, the
automatically offset value is set to this parameter.
The initial value is provided before shipment by the
automatic VC offset function on condition that the
voltage between VC and LG is 0 V.
Setting range: -9999 to 9999
Analog speed limit offset
Used to set the offset voltage of the analog speed
limit (VLA).
For example, if CCW rotation is provided by
switching on forward rotation selection (RS1) with 0
V applied to VLA, set a negative value.
When automatic VC offset is used, the
automatically offset value is set to this parameter.
The initial value is the value provided by the
automatic VC offset function before shipment at the
VLA-LG voltage of 0 V.
Analog speed limit offset
Set the offset voltage of VLA (Analog speed limit).
For example, if CCW rotation or positive direction
travel is provided by switching on RS1 (Forward
rotation selection) while applying 0 V to VLA, set a
negative value.
When automatic VC offset is used, the
automatically offset value is set to this parameter.
The initial value is provided before shipment by the
automatic VC offset function on condition that the
voltage between VLA and LG is 0 V.
Setting range: -9999 to 9999
T
PC38 Analog torque command offset
Used to set the offset voltage of the analog torque
command (TC).
0
PC38 Analog torque command offset
Set the offset voltage of TC (Analog torque
command).
Setting range: -9999 to 9999 mV
0 T
Analog torque limit offset
Used to set the offset voltage of the analog torque
limit (TLA).
Analog torque limit offset
Set the offset voltage of TLA (Analog torque limit).
Setting range: -9999 to 9999 mV
S
PC39 Analog monitor 1 offset
Used to set the offset voltage of the analog monitor
(MO1).
0 PC39
Same as MR-J3
0 P
S
T
Analog monitor 1 offset
Set the offset voltage of MO1 (Analog monitor 1).
Setting range: -9999 to 9999 mV
PC40 Analog monitor 2 offset
Used to set the offset voltage of the analog monitor
(MO2).
0 PC40
Same as MR-J3
0 P
S
T
Analog monitor 2 offset
Set the offset voltage of MO2 (Analog monitor 2).
Setting range: -9999 to 9999 mV
PC43
For manufacturer setting
Do not change this value by any means.
0000h
PC43 Error excessive alarm level
Set an error excessive alarm level.
You can change the setting unit with "Error
excessive alarm/error excessive warning level unit
selection" in [Pr. PC24].
Set this per rev. for rotary servo motors. Setting "0"
will be "3 rev", and setting over 200 rev will be
clamped with 200 rev.
Setting range: 0 to 1000
0 P
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...