Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 21
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PA14 Rotation direction selection
This parameter is made valid when power is switched
off, then on after setting, or when the controller reset has
been performed.
Select servo motor rotation direction relative.
[Pr. PA14]
setting
Servo motor rotation direction (Note1)
When positioning
address increases
(Position control)
Command speed in the
positive direction
(Speed control)
Command torque in the
positive direction
(Torque control (Note2))
When positioning
address decreases
(Position control)
Command speed in the
negative direction
(Speed control)
Command torque in the
negative direction
(Torque control (Note2))
0 CCW
CW
1 CW
CCW
Note 1. The torque generation direction for the torque
control.
2. The torque generation direction can be set for
the slave axis with this parameter by using the
master-slave operation function.
Forward rotation (CCW)
Reverse rotation (CW)
0 PA14
Rotation direction selection/travel direction selection
This is used to select a rotation direction or travel
direction.
For the setting for the master-slave operation function,
refer to "Part 6 section 6.2
"
.
Setting
value
Servo motor rotation direction
Positioning
address increase
Positioning
address decrease
0
CCW or
positive direction
CW or
negative direction
1
CW or
negative direction
CCW or
positive direction
The following shows the servo motor rotation directions.
Forward rotation (CCW)
Reverse rotation (CW)
0
PA15
Encoder output pulse
This parameter is made valid when power is switched
off, then on after setting, or when the controller reset has
been performed.
Used to set the encoder pulses (A-phase, B-phase)
output by the servo amplifier.
Set the value 4 times
greater than the A-phase or B-phase pulses.
You can use [Pr. PC03] to choose the output pulse
setting or output division ratio setting.
The number of A/B-phase pulses actually output is 1/4
times greater than the preset number of pulses.
The maximum output frequency is 4.6 Mpulses/s (after
multiplication by 4). Use this parameter within this range.
For output pulse designation
Set "_ _ 0 _" (initial value) in [Pr. PC03]
Set the number of pulses per servo motor revolution.
Output pulse set value [pulses/rev]
For instance, set "5600" to [Pr. PA15], the actually output
A/B-phase pulses are as indicated below.
4
5600
A B-phase output pulses
1400[pulse]
For output division ratio setting
Set "_ _ 1 _" in [Pr. PC03]
The number of pulses per servo motor revolution is
divided by the set value.
Output pulse
[pulses/rev]
Resolution per servo motor revolution
Set value
For instance, set "8" to [Pr. PA15], the actually output
A/B-phase pulses are as indicated below.
A
・
B-phase output pulses =
8
262144
・
4
1 = 8192 [pulse]
4000 PA15
Encoder output pulses
Set the encoder output pulses from the servo amplifier
by using the number of output pulses per revolution,
dividing ratio, or electronic gear ratio. (after multiplication
by 4)
To set a numerator of the electronic gear, select "A-
phase/B-phase pulse electronic gear setting (_ _ 3 _)" of
"Encoder output pulse setting selection" in [Pr. PC03].
The maximum output frequency is 4.6 Mpulses/s. Set the
parameter within this range.
4000
PA16 Encoder output pulses 2
Set a denominator of the electronic gear for the A/B-
phase pulse output. To set a denominator of the
electronic gear, select "A-phase/B-phase pulse
electronic gear setting (_ _ 3 _)" of "Encoder output
pulse setting selection" in [Pr. PC03].
1
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...