Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
3 - 17
3.6.3 Comparison of parameter details
MR-J3-_B_
MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PA01 Control mode
Turn off the power and then on again after setting the
parameter to validate the parameter value.
This parameter is supported by a combination of a servo
amplifier, whose software version is C4 or later
(manufactured in January 2010 or later), and a HF-KP
servo motor (manufactured in August 2009 or later).
Check the software version using status display or Setup
software (SETUP221E).
When the 350% maximum torque setting of the HF-KP
servo motor is enabled, set the torque limit value in the
controller at 1000%.
A HF-KP servo motor with a decelerator and servo
motors except the HF-KP series do not support the 350
maximum torque setting. Making the 350 maximum
torque setting valid when using these servo motors
causes the [AL. 37 parameter error].
Set the control loop composition of the servo amplifier,
and the maximum torque of the HFKP series servo
motor.
By making the high-response control valid in the control
loop composition, response of the servo can be
increased compared to the response under the standard
control (factory setting).Moreover, the track ability for a
command and the settling time in machines with high
rigidity can be decreased. To further shorten the settling
time using the auto tuning results of the high-response
control, increase the setting of model loop gain ([Pr.
PB07]) in the manual mode.
By making the 350 maximum torque setting valid, the
maximum torque of the HF-KP servo motor can be
increased from 300 to 350. To operate at the maximum
torque of 350, operate within the range of overload
protection characteristic. If operated beyond the overload
protection characteristic range, servo motor overheat
(46), overload 1 (50), and overload 2 (51) may occur.
0 x 0 0:
Control type selection
0: Standard control (350 maximum torque setting of HF-
KP servo motor Invalid)
3: Standard control (350 maximum torque setting of HF-
KP servo motor Valid)
4: High-response control valid (350 maximum torque
setting of HF-KP servo motor Invalid)
5: High-response control valid (350 maximum torque
setting of HF-KP servo motor Valid)
0000h
PA01 Operation
mode
Select an operation mode.
_ _ _ x:
For manufacturer setting
0h
_ _ x _ :
Operation mode selection
0: Standard control mode
Setting other than above will result in [AL. 37 Parameter
error].
0h
_ x _ _ :
For manufacturer setting
0h
x _ _ _ :
Operation mode selection
To change this digit, use an application software "MR-
J4(W)-B mode selection". When you change it without
the application, [AL. 3E Operation mode error] will occur.
0: J3 compatibility mode
1: J4 mode
1h
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...