(2) SSCNET III/H cable specifications
POINT
SSCNET III cables can be used as they are.
Description
SSCNET III/H cable model
MR-J3BUS_M MR-J3BUS_M-A
MR-J3BUS_M-B
SSCNET III/H cable length
0.15 m
0.3 m to 3 m
5 m to 20 m
30 m to 50 m
Optical cable
(cord)
Minimum bend
radius
25 mm
Enforced covering cable:
50 mm
Cord: 25 mm
Enforced covering cable:
50 mm
Cord: 30 mm
Tension strength
70 N
140 N
420 N
(Enforced covering cable)
980 N
(Enforced covering cable)
Temperature
range for use
(Note)
-40 °C to 85 °C
-20 °C to 70 °C
Atmosphere
Indoors (not exposed to direct sunlight), no solvent or oil.
Appearance [mm]
2.2 0.07
4.4 0.1
2.2
0.0
7
4.4 0.1
6.0 0.2
2.
2
0.
07
4.4 0.4
7.6 0.5
2.
2
0.
2
Note. This temperature range for use is the value for optical cable (cord) only. Temperature condition for the connector is the same as
that for servo amplifier.
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...