Part 4: Replacement of MR-J3W-_B with MR-J4W2-_B
4 - 34
MR-J3W-_B MR-J4W2-_B
No.
Name and function
Initial
value
No.
Name and function
Initial
value
PB17 Automatic setting parameter
The value of this parameter is set according to a set
value of [Pr. PB06] (Load to motor inertia moment ratio).
PB17 Shaft resonance suppression filter
Set a shaft resonance suppression filter.
When you select "Automatic setting (_ _ _ 0)" of "Shaft
resonance suppression filter selection" in [Pr. PB23], the
value will be calculated automatically from the servo
motor you use and load to motor inertia ratio. When
"Manual setting (_ _ _ 1)" is selected, the setting written
to the parameter is used.
When "Shaft resonance suppression filter selection" is
"Disabled (_ _ _ 2)" in [Pr. PB23], the setting value of
this parameter will be disabled.
When you select "Enabled (_ _ _ 1)" of "Machine
resonance suppression filter 4 selection" in [Pr. PB49],
the shaft resonance suppression filter is not available.
_ _ x x:
Shaft resonance suppression filter setting frequency
selection.This is used for setting the shaft resonance
suppression filter.Refer to table 4.3 for settings.
Set the value closest to the frequency you need.
00h
_ x _ _ :
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
x _ _ _ :
For manufacturer setting
0h
Table 4.3 Shaft resonance suppression filter setting
frequency selection
Setting
value
Frequency [Hz]
Setting
value
Frequency [Hz]
_ _ 0 0
Disabled
_ _ 1 0
562
_ _ 0 1
Disabled
_ _ 1 1
529
_ _ 0 2
4500
_ _ 1 2
500
_ _ 0 3
3000
_ _ 1 3
473
_ _ 0 4
2250
_ _ 1 4
450
_ _ 0 5
1800
_ _ 1 5
428
_ _ 0 6
1500
_ _ 1 6
409
_ _ 0 7
1285
_ _ 1 7
391
_ _ 0 8
1125
_ _ 1 8
375
_ _ 0 9
1000
_ _ 1 9
360
_ _ 0 A
900
_ _ 1 A
346
_ _ 0 B
818
_ _ 1 B
333
_ _ 0 C
750
_ _ 1 C
321
_ _ 0 D
692
_ _ 1 D
310
_ _ 0 E
642
_ _ 1 E
300
_ _ 0 F
600
_ _ 1 F
290
PB18 Low-pass filter setting
Set the low-pass filter.
Setting [Pr. PB023] (low-pass filter selection) to "_ _ 0 _"
automatically changes this parameter.
When [Pr. PB023] is set to "_ _ 1 _" , this parameter can
be set manually.
3141
PB18 Low-pass filter setting
Set the low-pass filter.
The following shows a relation of a required parameter
to this parameter.
[Pr. PB23]
[Pr. PB18]
_ _ 0 _ (Initial value)
Automatic setting
_ _ 1 _
Setting value enabled
_ _ 2 _
Setting value disabled
3141
Содержание Melservo MR-J3-100B
Страница 17: ...8 MEMO ...
Страница 18: ...Part 1 Summary of MR J3 MR J3W Replacement 1 1 Part 1 Summary of MR J3 MR J3W Replacement ...
Страница 145: ...Part 3 Review on Replacement of MR J3 _B_ with MR J4 _B_ 3 48 MEMO ...
Страница 146: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 1 Part 4 Review on Replacement of MR J3W _B with MR J4W2 _B ...
Страница 195: ...Part 4 Replacement of MR J3W _B with MR J4W2 _B 4 50 MEMO ...
Страница 196: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 1 Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ ...
Страница 277: ...Part 5 Review on Replacement of MR J3 DU_ with MR J4 DU_ 5 82 MEMO ...
Страница 278: ...Part 6 Common Reference Material 6 1 Part 6 Common Reference Material ...
Страница 418: ...Part 7 Review on Replacement of Motor 7 1 Part 7 Review on Replacement of Motor ...
Страница 564: ...Part 9 Startup Procedure Manual 9 1 Part 9 Startup Procedure Manual ...
Страница 567: ...Part 9 Startup Procedure Manual 9 4 MEMO ...
Страница 589: ...L NA 03127ENG C ...