2. Wiring and Connection
2-24
Examples of Connecting Analog Output Signals
Caution
1.
Refer to "5.2.3 Assignment of Analog Output Signals" for signal settings and scale adjustment.
2.
The range of analog output signals is -10V to 10V.
3.
The resolution of analog output signal is 12 bits.
4.
The maximum load current allowed is 2.5 mA.
5.
The stabilization time is 15 us.
ANALOG MONITOR1
Servo Drive
AGND
ANALOG MONITOR2