10. Object Dictionary
10-111
0x6063
Position Actual Internal Value
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
DINT
-
-
pulse
RO
Yes
-
No
This parameter displays the position actual internal value in the unit of encoder pulse.
0x6064
Position Actual Value
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
DINT
-
-
UU
RO
Yes
-
No
This parameter displays the position actual value in a user-defined position unit (UU).
0x6065
Following Error Window
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UDINT
0 to 0x3FFFFFFF
600000
UU
RW
No
Always
Yes
This sets the following error window to check the Following Error (Statusword, 0x6041.13).
0x6066
Following Error Timeout
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 65535
0
ms
RW
No
Always
Yes
This sets the timeout for when checking the Following Error (Statusword, 0x6041.13).
Содержание L7NHF Series
Страница 2: ......
Страница 14: ...Table of Contents xii ...
Страница 60: ...2 Wiring and Connection 2 38 ...
Страница 158: ...6 Safety Functions 6 6 ...
Страница 172: ...7 Tuning 7 14 ...
Страница 182: ...8 Procedure Function 8 10 ...
Страница 192: ...9 Full Closed Control 9 10 ...
Страница 214: ...10 Object Dictionary 10 22 ...
Страница 363: ...11 Product Specifications 11 43 ...
Страница 364: ......