9. Full-Closed Control
9-9
Example of setting the dual-feedback filter time constant
H. Setting the dual-feedback filter time constant
0x2029
Load Feedback Type
ALL
Variable
Type
Setting Range
Initial
Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1
0
-
RW
No
Power
cycling
Yes
This setting determines that you can select linear type or rotary type in the load encoder type.
0 : Rotary / 1 : Linear
Time
Remaining
pulse
Command
Pulse
Time
Remaining
pulse
Command
Pulse
Shortens the time for position adjustment
Weighted value of semi-closed control
increases.
Increase the size of the dual feedback filter.
Weighted value of the motor-side encoder
increases.
Decrease the size of the dual feedback filter.
Weighted value of the load-side encoder
increases.
Vibrations suppressed
Weighted value of full-closed control increases.