10. Object Dictionary
10-36
0x2013
Emergency Stop Configuration
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1
1
-
RW
No
Always
Yes
You can set the method of emergency stop (for POT, NOT, or ESTOP input). In torque control mode,
the deceleration stop mode which uses emergency stop torque is not applied.
Setting
Value
Description
0
The motor stops according to the method set in Dynamic Brake Control Mode
(0x2012).
It stops using the dynamic brake and maintains the torque command at 0.
1
The motor decelerates to a stop using the emergency stop torque (0x2113).
0x2014
Warning Mask Configuration
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to FFFF
hex
0
-
RW
Yes
Always
Yes
Warnings masked by this setting are not triggered.
Bits
Warning
Codes
Warning name/description
0
W01
Main power phase loss
1
W02
Low voltage of encoder battery
2
W04
Software position limit
3
-
-
4
W10
Operation overload
5
W20
Abnormal combination of drive and motor, abnormal I/O
setting
6
W40
Low voltage
7
W80
Emergency signal input
8 to 13
-
-
14
AL-34
Encoder phase Z loss alarm mask
15
STO
Status word fault bit setting when STO is not connected
Содержание L7NHF Series
Страница 2: ......
Страница 14: ...Table of Contents xii ...
Страница 60: ...2 Wiring and Connection 2 38 ...
Страница 158: ...6 Safety Functions 6 6 ...
Страница 172: ...7 Tuning 7 14 ...
Страница 182: ...8 Procedure Function 8 10 ...
Страница 192: ...9 Full Closed Control 9 10 ...
Страница 214: ...10 Object Dictionary 10 22 ...
Страница 363: ...11 Product Specifications 11 43 ...
Страница 364: ......