10. Object Dictionary
10-76
0x2407
BRAKE Output Speed
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 6000
100
rpm
RW
No
Always
Yes
If the motor stops due to the servo off state or servo alarm during rotation, you can set the velocity
(0x2407) and delay time (0x2408) for brake signal output in order to set the output timing. The
brake signal is output if the motor rotation velocity goes below the set value (0x2407) or the output
delay time (0x2408) has been reached after the servo off command.
0x2408
BRAKE Output Delay Time
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
100
ms
RW
No
Always
Yes
Refer to the description of 0x2407.
0x2409
Torque Limit for Homing Using Stopper
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 2000
250
0.1%
RW
No
Always
Yes
You can set torque limits for homing using the stopper. With too large of a value configured, the
machine may collide with the stopper. So be careful.
0x240A
Duration Time for Homing Using Stopper
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
50
ms
RW
No
Always
Yes
You can set the time to detect the stopper during homing. Set an appropriate value for the machine.
Содержание L7NHF Series
Страница 2: ......
Страница 14: ...Table of Contents xii ...
Страница 60: ...2 Wiring and Connection 2 38 ...
Страница 158: ...6 Safety Functions 6 6 ...
Страница 172: ...7 Tuning 7 14 ...
Страница 182: ...8 Procedure Function 8 10 ...
Страница 192: ...9 Full Closed Control 9 10 ...
Страница 214: ...10 Object Dictionary 10 22 ...
Страница 363: ...11 Product Specifications 11 43 ...
Страница 364: ......