10. Object Dictionary
10-60
0x211F
Drive Control Input 1
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to FFFF
hex
0
-
RW
Yes
Always
No
You can input the signal required for drive control via the I/O. Using a remote I/O, you can indirectly
input the control input signal, inputted to the upper level controller, to the drive through this setting.
An applicable function will be performed by logical OR operation of the signal received through the
I/O and the bit value of this setting.
Bits
Setting details
Bits
Setting details
0
POT
8
PROBE1
1
NOT
9
PROBE2
2
HOME
10
EMG
3
STOP
11
A_RST
4
PCON
12
SV_ON
5
GAIN2
13
LVSF1
6
P_CL
14
LVSF2
7
N_CL
15
Reserved
0x211F
Drive Control Input 1
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to FFFF
hex
0
-
RW
Yes
Always
No
Bits
Setting details
15-0
Reserved