10. Object Dictionary
10-79
Enhanced Control(0x2500~ )
0x2500
Adaptive Filter Function Select
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 5
0
-
RW
No
Always
Yes
You can set the adaptive filter function.
Setting Value
Setting details
0
The adaptive filter is not used
1
Only one adaptive filter is used. You can check the settings
configured automatically in the notch filter 3 settings (0x2507,
0x2508, 0x2509).
If an arbitrary value is set in notch filter 3, auto setting is not
available. If you wish to use auto setting, you should initialize notch
filter 3 first.
2
Two adaptive filters are used. You can check the settings
configured automatically in the notch filter 3 (0x2507, 0x2508,
0x2509) and filter 4 settings (0x250A, 0x250B, 0x250C).
If an arbitrary value is set for notch filter 3 (or 4), auto setting is
applied to notch filter 4 (or 3). If arbitrary values are set for notch
filter 3 and 4, the original settings remain unchanged. If notch filter 3
and 4 are initialized, auto setting is available.
3
Reserved
4
Resets the notch filter 3 (0x2507, 0x2508, and 0x2509) and notch
filter 4 (0x250A, 0x250B, and 0x250C) settings.
5
Reserved
0x2501
Notch Filter 1 Frequency
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
50 to 5000
5000
Hz
RW
No
Always
Yes
You can set the frequency of Notch Filter 1.
Содержание L7NHF Series
Страница 2: ......
Страница 14: ...Table of Contents xii ...
Страница 60: ...2 Wiring and Connection 2 38 ...
Страница 158: ...6 Safety Functions 6 6 ...
Страница 172: ...7 Tuning 7 14 ...
Страница 182: ...8 Procedure Function 8 10 ...
Страница 192: ...9 Full Closed Control 9 10 ...
Страница 214: ...10 Object Dictionary 10 22 ...
Страница 363: ...11 Product Specifications 11 43 ...
Страница 364: ......