10. Object Dictionary
10-5
0x1011
Restore Default Parameters
SubIndex 0
Number of Entries
Variable
Type
Setting Range
Initial Value
Unit
Accessibil
ity
PDO
Assignment
Variable
Attribute
Saving
USINT
-
4
-
RO
No
-
No
SubIndex 1
Restore all parameters
Variable
Type
Setting Range
Initial Value
Unit
Accessibil
ity
PDO
Assignment
Variable
Attribute
Saving
UDINT
0 to 0xFFFFFFFF
0
-
RW
No
-
No
SubIndex 2
Restore communication parameters
Variable
Type
Setting Range
Initial Value
Unit
Accessibil
ity
PDO
Assignment
Variable
Attribute
Saving
UDINT
0 to 0xFFFFFFFF
0
-
RW
No
-
No
SubIndex 3
Restore CiA402 parameters
Variable
Type
Setting Range
Initial Value
Unit
Accessibil
ity
PDO
Assignment
Variable
Attribute
Saving
UDINT
0 to 0xFFFFFFFF
0
-
RW
No
-
No
SubIndex 4
Restore drive-specific parameters
Variable
Type
Setting Range
Initial Value
Unit
Accessibil
ity
PDO
Assignment
Variable
Attribute
Saving
UDINT
0 to 0xFFFFFFFF
0
-
RW
No
-
No
Initialize the drive's parameters. To avoid any mistake, initialize the parameters if the ASCII code
value corresponding to 'save' is written to the relevant SubIndex value.
0x64
0x6C
MSB
LSB
16 15
0x6F
0x61
d
l
o
a
ASCII
코드
All parameters within the drive are initialized when “load” is written to SubIndex 1.
Only communication parameters (from 0x1000) are initialized when "load" is written to SubIndex 2.
Only CiA402 parameters (from 0x6000) are initialized when "load" is written to SubIndex 3.
Only drive-specific parameters (from 0x2000) are initialized when "load" is written to SubIndex 4.
To apply the initialized value, you need to cycle the power of the drive.
Содержание L7NHF Series
Страница 2: ......
Страница 14: ...Table of Contents xii ...
Страница 60: ...2 Wiring and Connection 2 38 ...
Страница 158: ...6 Safety Functions 6 6 ...
Страница 172: ...7 Tuning 7 14 ...
Страница 182: ...8 Procedure Function 8 10 ...
Страница 192: ...9 Full Closed Control 9 10 ...
Страница 214: ...10 Object Dictionary 10 22 ...
Страница 363: ...11 Product Specifications 11 43 ...
Страница 364: ......