10. Object Dictionary
10-65
0x2211
Digital Output Signal 2 Selection
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 0xFFFF
0x8002
-
RW
No
Always
Yes
This sets the digital output signal 2 function and output signal level of the I/O. For more information,
refer to the description of 0x2210.
0x2212
Digital Output Signal 3 Selection
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 0xFFFF
0x0003
-
RW
No
Always
Yes
This sets the digital output signal 3 function and output signal level of the I/O. For more information,
refer to the description of 0x2210.
0x2220
Analog Monitor Output Mode
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1
0
-
RW
No
Always
Yes
The output range of the analog monitor is from -10 V to +10 V. If the setting is 1, take the absolute
value of the output so the output values is only positive.
Setting Value
Setting details
0
Output as negative/positive values
1
Output as positive values only
Содержание L7NHF Series
Страница 2: ......
Страница 14: ...Table of Contents xii ...
Страница 60: ...2 Wiring and Connection 2 38 ...
Страница 158: ...6 Safety Functions 6 6 ...
Страница 172: ...7 Tuning 7 14 ...
Страница 182: ...8 Procedure Function 8 10 ...
Страница 192: ...9 Full Closed Control 9 10 ...
Страница 214: ...10 Object Dictionary 10 22 ...
Страница 363: ...11 Product Specifications 11 43 ...
Страница 364: ......