5. Drive Application Functions
5-28
5.7
Positive/Negative Limit Setting
This function is used to safely operate the drive within the movable range of the apparatus using the
positive/negative limit signals of the drive. Be sure to connect and set the limit switch for safe operation.
For more information about the settings, refer to 5.2.1 Assignment of Digital Input Signals.
POT
NOT
I/O Pin 11
(default assigned value)
I/O Pin 12
(default assigned value)
When a positive/negative limit signal is input, the motor stops according to the emergency stop
configuration (0x2013).
Setting
Value
Description
0
The motor stops according to the method set in Dynamic Brake Control
Mode (0x2012).
It stops using the dynamic brake and maintains the torque command at 0.
1
The motor decelerates to a stop using the emergency stop torque (0x2113).
Related Objects
Index
Sub
Index
Name
Variable
Type
Accessibility
PDO
Assignment
Unit
0x2012
-
Dynamic Brake Control Mode
UINT
RW
No
-
0x2013
-
Emergency Stop Configuration
UINT
RW
No
-
0x2113
-
Emergency Stop Torque
UINT
RW
Yes
-