4. CiA402 Drive Profile
4-14
Related Objects
Index
Sub
Index
Name
Variable
Type
Accessibility
PDO
Assignment
Unit
0x6040
-
Controlword
UINT
RW
Yes
-
0x6041
-
Statusword
UINT
RO
Yes
-
0x60FF
-
Target Velocity
DINT
RW
Yes
UU/s
0x6084
-
Profile Deceleration
UDINT
RW
No
UU/s
2
0x6085
-
Quick Stop Deceleration
UDINT
RW
No
UU/s
2
0x60B1
-
Velocity Offset
DINT
RW
Yes
UU/s
0x60B2
-
Torque Offset
INT
RW
Yes
0.1%
0x606B
-
Velocity Demand Value
DINT
RO
Yes
UU
0x606C
-
Velocity Actual Value
DINT
RO
Yes
UU/s
0x606D
-
Velocity Window
UINT
RW
No
UU/s
0x606E
-
Velocity Window Time
UINT
RW
No
ms
0x6077
-
Torque Actual Value
INT
RO
Yes
0.1%
0x606C
-
Velocity Actual Value
DINT
RO
Yes
UU/s
0x6064
-
Position Actual Value
DINT
RO
Yes
UU
0x6063
-
Position Actual Internal Value
DINT
RO
Yes
pulse