10. Object Dictionary
10-29
0x2008
7SEG Display Selection
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 100
0
-
RW
Yes
Always
Yes
You can set items to display in the 7SEG window.
Setting
Displayed Items
Unit
Description
0
Operation Status
-
1
Speed feedback
rpm, mm/s
2
Speed command
rpm, mm/s
3
Torque feedback
0.1%
4
Torque command
0.1%
5
Accumulated operation
overload
0.1%
6
DC link voltage
V
7
Accumulated regeneration
overload
0.1%
8
Mechanical Angle
0.1deg
9
Electrical Angle
0.1deg
10
Inertia ratio
%
11
Drive temperature 1
°C
Temperature near drive power element
12
Drive temperature 2
°C
Internal temperature of the drive
13
Encoder temperature 1
°C
Internal temperature of the encoder
14
Node ID
-
15
Instantaneous Maximum
Load Factor
0.1%
Instantaneous maximum load factor for
15 seconds
16
Root Mean Square (RMS)
Load Factor
0.1%
Root mean square (RMS) load factor for
15 seconds