10. Object Dictionary
10-56
0x2114
P/PI Control Conversion Mode
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 4
0
-
RW
Yes
Always
Yes
You can set the switch mode between PI control and P control. Using this function, you can
improve the velocity control characteristic to reduce overshoot during velocity operation and
positioning time during position operation.
Setting Value
Setting details
0
Always use PI control
1
Switches to P control if the command torque is larger than the P control
switch torque (0x2115)
2
Switches to P control if the command speed is larger than the P control
switch speed (0x2116)
3
Switches to P control if the acceleration command is larger than the P
control switch acceleration (0x2117)
4
Switches to P control if the following error is larger than the P control
switch following error (0x2118)
0x2115
P Control Switch Torque
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 5000
500
0.1%
RW
Yes
Always
Yes
Refer to the description of P/PI Control Conversion Mode (0x2114).
0x2116
P Control Switch Speed
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 6000
100
rpm
RW
Yes
Always
Yes
Refer to the description of P/PI Control Conversion Mode (0x2114).
Содержание L7NHF Series
Страница 2: ......
Страница 14: ...Table of Contents xii ...
Страница 60: ...2 Wiring and Connection 2 38 ...
Страница 158: ...6 Safety Functions 6 6 ...
Страница 172: ...7 Tuning 7 14 ...
Страница 182: ...8 Procedure Function 8 10 ...
Страница 192: ...9 Full Closed Control 9 10 ...
Страница 214: ...10 Object Dictionary 10 22 ...
Страница 363: ...11 Product Specifications 11 43 ...
Страница 364: ......