4. CiA402 Drive Profile
4-34
(A) The initial driving direction is negative (CW), and the drive operates at the switch search speed.
(B) When the drive hits the negative stopper, it stands by according to the torque limit value (0x2409) and the time setting
value (0x240A) during homing using the stopper, then switches the direction.
(C) While operating at the zero search speed, the drive detects the first index pulse to move to the index position (Home).
Speed
Time
Positive Stopper
Index Pulse
(A)
(B)
(C)
Homing Method
Torque setting
(0x2409)
Time setting (0x240A)
-2
Zero search speed
(0x6099:02)
Switch search speed
(0x60999:01)
(A) The initial driving direction is positive (CCW), and the drive operates at the switch search speed.
(B) When the drive hits the positive stopper, it stands by according to the torque limit value (0x2409) and the time setting
value (0x240A) during homing using the stopper, then switches the direction.
(C) While operating at the zero search speed, the drive detects the first index pulse to move to the index position (Home).