4. CiA402 Drive Profile
4-37
(2) At the start of homing, when the Home switch is off and the limit is met during operation
Speed
Negative Limit switch ON
(A)
(B)
Homing Method
Time
-5
Switch search speed
(0x6099:01)
Homing error
(A) The initial driving direction is negative (CW), and the drive operates at the switch search speed.
(B) When the negative limit switch is turned on, the drive issues a homing error and decelerates to a stop.
Speed
Time
Positive home switch ON
(A)
(B)
Homing Method
-6
Switch search speed
(0x6099:01)
Homing completion
(A) The initial driving direction is positive (CCW), and the drive operates at the switch search speed.
(B) If the positive home switch is turned on, the drive decelerates to a stop and completes homing.