10. Object Dictionary
10-39
0x201B
Commutation Current
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
500
0.1%
RW
No
Always
Yes
You can set the commutation current used to get information on the initial angle of the motor.
0x201C
Commutation Time
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
500 to 5000
1000
ms
RW
No
Always
Yes
You can set the commutation time used to get information on the initial angle of the motor.
0x201D
Grating Period of Sinusoidal Encoder
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
1 to 65535
40
um
RW
No
Power
cycling
Yes
You can set the grating period of sinusoidal encoder.
0x201E
Homing Done Behaviour
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1
0
-
RW
No
Always
Yes
This specifies whether to move to the zero position by Home Offset[0x607C] after homing is
completed.
Содержание L7NHF Series
Страница 2: ......
Страница 14: ...Table of Contents xii ...
Страница 60: ...2 Wiring and Connection 2 38 ...
Страница 158: ...6 Safety Functions 6 6 ...
Страница 172: ...7 Tuning 7 14 ...
Страница 182: ...8 Procedure Function 8 10 ...
Страница 192: ...9 Full Closed Control 9 10 ...
Страница 214: ...10 Object Dictionary 10 22 ...
Страница 363: ...11 Product Specifications 11 43 ...
Страница 364: ......