13. Test Drive
13-4
13.2
Test Drive Using TwinCAT System Manager
Test Drive Procedure
Order
Handling
Notes
1
Before launching the TwinCAT System Manager, copy the servo drive XML file
into the schema folder (C:\TwinCAT\Io\EtherCAT).
2
Launch the TwinCAT System Manager.
3
Select a Target System.
When performing the test drive using a remote system, select the device.
4
Restart the TwinCAT System with Config Mode.
Using the Set/Reset TwinCAT to Config Mode icon under the TwinCat
System Manager, you can restart the system with Config Mode.
5
Search for EtherCAT communication-based devices connected to the system.
Right-click I/O Devices in the Work Space pane of the TwinCAT system,
and then click Scan Devices.
If the dialog window below appears in the TwinCAT System Manager, click
OK.