4. CiA402 Drive Profile
4-40
Continuous Trigger Mode (0x60B8.1=1, 0x60B8.9=1):
In continuous trigger mode, bits 6, 7, 14, and 15 of the touch probe status (0x60B9) toggle (0
1 or 1
0) every time the corresponding input/edge is input.
0x60B8.0
(0x60B8.8)
0x60B8.4
(0x60B8.12)
0x60B9.0
(0x60B9.8)
Probe input
0x60B9.1
(0x60B9.9)
0x60BA
(0x60BC)
Position 1 Latched
Position 3 Latched
Latch start
1
2
3
Position 2 Latched
0x60B9.6
(0x60B9.14)
Index Pulse Trigger Mode (0x60B8.2=1, 0x60B8.10=1):
0x60B8.0
(0x60B8.8)
Index(Z) Pulse
0x60B9.6
(0x60B9.14)
0x60B8.2
(0x60B9.10)
0x60BA
(0x60BC)
Position 1
Latched
0x60B8.1
(0x60B9.9)
1
2
3
4
5
6
7
8
9
Position 5
Latched
Position 6
Latched
Position 7
Latched
Position 8
Latched
Position 9
Latched
Single Trigger mode
Continuous Trigger mode