TOS6200A/6210
Basic Operation
4-9
Resistance value-based judgment
Set a lower reference value as follows:
TOS6200A: 0.001
to 1.200
(resolution: 0.001
).
TOS6210: 0.001
to 0.600
(resolution: 0.001
).
1.
Press the F2 (LOWER) key if the lower reference value is not displayed
on the LCD. (You can also use the
▲▼
keys to move the cursor
when the lower reference value is displayed.)
2.
Use the
keys to move the cursor to the desired digit.
3.
Use the rotary knob to set a lower reference value.
“UP <= LOW” blinks on the LCD.
If a lower reference value more than the upper reference value is set when lower
limit judgment is ON, the “READY” indication in the upper right of the LCD
changes to blink “UP <= LOW,” informing you that testing cannot begin under
the current conditions. In this case, increase the upper reference value or reduce
the lower reference value.
CURRENT LOWER UPPER
TIMER
25.0
A
0.003 60.0
s
MAIN
MAIN
FREQ
LOWER
ON
OFFSET
OFF
TIMER
ON
READY
50Hz
LOWER
F1 F2 F3 F4 F5
▲
▲
▲
▲
Содержание TOS6200A
Страница 1: ...Part No IB028661 Mar 2015 USER S MANUAL EARTH CONTINUITY TESTER TOS6200A TOS6210...
Страница 14: ...1 8 General TOS6200A 6210...
Страница 26: ...2 12 Installation and Preparation for Use TOS6200A 6210...
Страница 34: ...3 8 Part Names and Functions TOS6200A 6210...
Страница 76: ...4 42 Basic Operation TOS6200A 6210...
Страница 134: ...7 6 Maintenance TOS6200A 6210...
Страница 150: ...A 8 Appendix TOS6200A 6210...
Страница 153: ...TOS6200A 6210 Index I 3 U Unpacking 2 2 UP LOW 4 35 Upper reference value 4 5 V VOLT LIMIT 4 39...