8-6
Specifications
TOS6200A/6210
8.3
General Specifications
Item
TOS6200A
TOS6210
Environment
Operating environment
Indoor use, Overvoltage Category II
Warranty
range
Temperature
5
C to 35
C (41
F to 95
F)
Humidity
20 %rh to 80 %rh (non condensing)
Operating
range
Temperature
0
C to 40
C (32
F to 104
F)
Humidity
20 %rh to 80 %rh (non condensing)
Storage
range
Temperature
-20
C to +70
C (-4
F to +158
F)
Humidity
90 %rh or less (non condensing)
Altitude
Up to 2000 m
Power requirement
Allowable voltage range
85 Vac to 250 Vac
Power con-
sumption
At no load
(READY)
60 VA or less
At rated load
280 VA max.
420 VA max.
Allowable frequency range
47Hz to 63Hz
Insulation resistance
30M
min. (500 Vdc), between AC line and chassis
Withstanding voltage
1390 Vac (2 seconds), between AC line and chassis
Earth continuity
25 Aac/ 0.1
max.
Safety *4
Conforms to the requirements of the following directive and standard.
Low Voltage Directive 2006/95/EC *5
EN 61010-1 (Class I
, Pollution degree 2)
Electromagnetic compatibility
(EMC) *4, *5
Conforms to the requirements of the following directive and standard.
EMC Directive 2004/108/EC
EN 61326-1 (Class A
)
EN 55011 (Class A
, Group 1
)
EN 61000-3-2
EN 61000-3-3
Under following conditions
1. Used test leadwire (TL11-TOS for TOS6200A, TL12-TOS for TOS6210)
which is supplied.
2. Used the shielded cable which length is less than three meters when the SIG-
NAL I/O is used.
*4
Not applicable to custom order models.
*5
Only on models that have CE marking on the panel.
*6
This instrument is a Class I equipment. Be sure to ground the protective conductor terminal of the instrument. The
safety of the instrument is not guaranteed unless the instrument is grounded properly.
*7
This is a Class A equipment. This product is intended for use in an industrial environment. This product may cause
interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce
electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*8
This is a Group I equipment. This product does not generate and/or use intentionally radio-frequency energy, in the
form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/
analysis purpose.
Содержание TOS6200A
Страница 1: ...Part No IB028661 Mar 2015 USER S MANUAL EARTH CONTINUITY TESTER TOS6200A TOS6210...
Страница 14: ...1 8 General TOS6200A 6210...
Страница 26: ...2 12 Installation and Preparation for Use TOS6200A 6210...
Страница 34: ...3 8 Part Names and Functions TOS6200A 6210...
Страница 76: ...4 42 Basic Operation TOS6200A 6210...
Страница 134: ...7 6 Maintenance TOS6200A 6210...
Страница 150: ...A 8 Appendix TOS6200A 6210...
Страница 153: ...TOS6200A 6210 Index I 3 U Unpacking 2 2 UP LOW 4 35 Upper reference value 4 5 V VOLT LIMIT 4 39...