Keysight 5500 SPM User’s Guide
5-18
10 V, beyond which the signal will be clipped. The
default value is x1 (the amplitude times 1).
Drive Mechanism The mechanism (AAC, MAC or Top MAC).
Zero Phase
Sets the phase at the current frequency to zero,
making it easier to interpret phase changes from
the current value.
Q Control On
By applying a phase-shifted version of the
cantilever deflection signal on top of the drive
signal, Q control can either increase or decrease the
effective quality factor of the system. Select this
On
check box to enable the Q Control feedback
loop. By default, Q Control is turned Off.
Drive (%)
Sets the amplitude of the Q Control phase-shifted
signal, stated as a percentage (0-100 %) of the
maximum available.
Optimize
Sets the optimal Q-Control Phase Shift and Drive.
On the Output tab, the
Pass Through
check boxes for Deflection and
Friction are selected, passing these values from the microscope through
to the AFM controller.
Amplitude 1 and Phase 1 are routed to the Aux 1 and Aux 2 outputs,
respectively, to be used as inputs to image buffers. These signals can be
viewed by selecting Aux 1 or Aux 2 from the drop-down list in the
Realtime Images window.
EFM
In EFM Mode, Lock-in 1 is used to drive the cantilever, with the
Deflection channel as its Input. Lock-in 2 provides an AC tip bias, also
with the Deflection channel as its Input. The actual Deflection input
during scanning is the oscillation amplitude.
NOTE
For EFM mode, the Bias switch on the back of the Head Electronics
Box must be set to
Tip
.
Содержание 5500
Страница 1: ...Keysight 5500 Scanning Probe Microscope User s Guide ...
Страница 2: ......
Страница 9: ...Read This First N9410 90001 Keysight 5500 SPM User s Guide ix Declaration of Conformity ...
Страница 174: ...Additional Imaging Modes 5 Keysight 5500 SPM User s Guide 5 40 Figure 7 23 Plug in Images window ...
Страница 215: ...Closed Loop Scanners 5 Keysight 5500 SPM User s Guide 5 17 Save the calibration file X Y Z calibration is now complete ...
Страница 274: ...Temperature Control 5 Keysight 5500 SPM User s Guide 5 8 Figure 13 10 7500 9500 hot sample plate wiring diagram ...
Страница 275: ...Temperature Control 5 Keysight 5500 SPM User s Guide 5 9 Figure 13 11 5500 hot MAC sample plate wiring diagram ...
Страница 276: ...Temperature Control 5 Keysight 5500 SPM User s Guide 5 10 Figure 13 12 7500 9500 hot MAC sample plate wiring diagram ...
Страница 284: ...Temperature Control 5 Keysight 5500 SPM User s Guide 5 18 Figure 13 21 5500 Peltier Cold sample plate wiring diagram ...
Страница 297: ...Thermal K 5 Keysight 5500 SPM User s Guide 5 9 Figure 14 8 Select units after calibrating the Force Constant ...
Страница 330: ...Keysight Technologies 5500 SPM User s Guide Part Number N9410 90001 Revision H Keysight Technologies 2015 ...