MAC Mode
5
Keysight 5500 SPM User’s Guide
5-3
4
Deflection output from detector.
5
Amplitude output from lock-in amplifier.
6
Phase shift signal from lock-in amplifier.
7
To Serial Port on computer.
8
Aux output for custom applications.
9
44-pin cable from AFM Controller.
10
44-pin cable to Head Electronics Box.
11
25-pin cable (if applicable).
12
25-pin cable to HEB (if applicable).
In addition to the standard cabling for your microscope, the following
connections must be made to use the MAC Mode in your system (a
complete wiring diagram is included in
Power Cord
Connect the power cord from the back of the MAC
Mode controller to building power. Do not power on the controller at
this time.
Computer Connection
Connect the RS-232 serial cable from the
SERIAL port on the MAC Mode controller to a COM port on your
computer. The port number will be automatically detected if your
computer has more than one COM port.
Head Electronics Box Connection
Connect the short DB44 cable
from the MAC Mode Controller to the CONTROLLER connector on
the Head Electronics box (HEB). Use a DB44 cable between the
MICROSCOPE connector on the HEB and the 44-pin connector on the
microscope.
AFM Controller Connection
Connect a DB44 cable from the MAC
Mode controller to the PicoSPM II connector on the AFM Controller.
Sample Plate Connection
Plug the round jack of the EC/MAC
cable into the underside of the microscope stand. Connect the MAC
cable connector of the EC/MAC cable (
6-pin connector on the sample plate using the MAC cable (
Содержание 5500
Страница 1: ...Keysight 5500 Scanning Probe Microscope User s Guide ...
Страница 2: ......
Страница 9: ...Read This First N9410 90001 Keysight 5500 SPM User s Guide ix Declaration of Conformity ...
Страница 174: ...Additional Imaging Modes 5 Keysight 5500 SPM User s Guide 5 40 Figure 7 23 Plug in Images window ...
Страница 215: ...Closed Loop Scanners 5 Keysight 5500 SPM User s Guide 5 17 Save the calibration file X Y Z calibration is now complete ...
Страница 274: ...Temperature Control 5 Keysight 5500 SPM User s Guide 5 8 Figure 13 10 7500 9500 hot sample plate wiring diagram ...
Страница 275: ...Temperature Control 5 Keysight 5500 SPM User s Guide 5 9 Figure 13 11 5500 hot MAC sample plate wiring diagram ...
Страница 276: ...Temperature Control 5 Keysight 5500 SPM User s Guide 5 10 Figure 13 12 7500 9500 hot MAC sample plate wiring diagram ...
Страница 284: ...Temperature Control 5 Keysight 5500 SPM User s Guide 5 18 Figure 13 21 5500 Peltier Cold sample plate wiring diagram ...
Страница 297: ...Thermal K 5 Keysight 5500 SPM User s Guide 5 9 Figure 14 8 Select units after calibrating the Force Constant ...
Страница 330: ...Keysight Technologies 5500 SPM User s Guide Part Number N9410 90001 Revision H Keysight Technologies 2015 ...