www.jps.com.tw
65
13. Flip-Flop Function Description
13.1 Pulse-Couter Group
13.1.1 Pulse-Counter Parameters
z
Pr.240
Æ
PULSE_COUNTER-Mon1
z
Pr.241
Æ
PULSE_COUNTER-Mon2
z
Pr.242
Æ
PULSE_COUNTER-Mon3
Upper parameters display each pulse-counter index value。
z
Pr.243
Æ
PULSE_FREQUENCY-Mon1
z
Pr.244
Æ
PULSE_FREQUENCY-Mon2
z
Pr.245
Æ
PULSE_FREQUENCY-Mon3
Upper parameters display each frequence of pulse-counter。
z
Pr.246
Æ
COMPARE_SET-1
z
Pr.247
Æ
COMPARE_SET-2
z
Pr.248
Æ
COMPARE_SET-3
Upper parameters set each compare-value of pulse-counter。
13.1.2 Pulse-Counter Digital Input
z
DIx_Select
Æ
27,Pulse-Counter-1 CLEAR to Zero
z
DIx_Select
Æ
28,Pulse-Counter-2 CLEAR to Zero
z
DIx_Select
Æ
29,Pulse-Counter-3 CLEAR to Zero
Upper functions clear each pulse-counter result to zero。
z
DIx_Select
Æ
31,Pulse-Counter-1 INPUT
z
DIx_Select
Æ
32,Pulse-Counter-2 INPUT
z
DIx_Select
Æ
33,Pulse-Counter-3 INPUT
When trigger each function,will add each result of pulse-counter。
13.1.3 Pulse-Counter Digital Output
z
DOx_Select
Æ
27,Pulse_Frequency-1 > COMPARE-Set1
Active when (Pr.243:Pulse_Frequency-1)>(Pr.246:COMPARE_SET-1)。
z
DOx_Select
Æ
28,Pulse_Frequency-1 > COMPARE-Set2
Active when (Pr.244:Pulse_Frequency-2)>(Pr.247:COMPARE_SET-2)。
z
DOx_Select
Æ
29,Pulse_Frequency-1 > COMPARE-Set3
Active when (Pr.245:Pulse_Frequency-1)>(Pr.248:COMPARE_SET-3)。
z
DOx_Select
Æ
31,Pulse-Counter-1 > COMPARE-Set1
Active when (Pr.240:PULSE_COUNTER-Mon1)>(Pr.246:COMPARE_SET-1)。
z
DOx_Select
Æ
32,Pulse-Counter-1 > COMPARE-Set2
Active when (Pr.241:PULSE_COUNTER-Mon2)>(Pr.247:COMPARE_SET-2)。
z
DOx_Select
Æ
33,Pulse-Counter-1 > COMPARE-Set3
Active when (Pr.242:PULSE_COUNTER-Mon3)>(Pr.248:COMPARE_SET-3)。
Содержание IRIS-IMSV
Страница 1: ...IRIS IMSV DRIVER USER MANUAL Version V5 03 ...
Страница 95: ...16 CE Certificate 16 1 EMC Certificate www jps com tw 94 ...
Страница 96: ...16 2 LVD Certificate www jps com tw 95 ...