www.jps.com.tw
27
No.
Name
Default
Min.
Max.
Unit
Type
GXX-XX
229 AI-1 Adc data
0
0
4095
--
M
03-00
230 AI-1 Positive Maximum Reference
4095
0
4095
--
FR/W
03-01
231 AI-1 Zero(/Middle) Reference
2048
0
4095
--
FR/W
03-02
232 AI-1 Negative Minimum Reference
0
0
4095
--
FR/W
03-03
233 AI-1 TYPE
0
0
1
--
R/W;R
03-04
234 AI-1 Command Value
0.00
0.00 100.00
%
M
03-05
235 AI-1 D-band Value
0
0
1000
--
R/W
03-06
477 AI-2 Adc data
0
0
4095
--
M
481 AI-2 Positive Maximum Reference
4095
0
4095
--
FR/W
482 AI-2 Zero(/Middle) Reference
2048
0
4095
--
FR/W
483 AI-2 Negative Minimum Reference
0
0
4095
--
FR/W
484 AI-2 TYPE
0
0
1
--
R/W;R
485 AI-2 Command Value
0.00
0.00 100.00
%
M
486 AI-2 D-band Value
0
0
1000
--
R/W
487 AI-2 Compare Set Value
50
0.00 100.00
%
R/W
488 AI-1 Compare Set Value
50
0.00 100.00
%
R/W
Analog Output Group <Refer to Chapter-10.5>
No.
Name
Default
Min.
Max.
Unit
Type
GXX-XX
370 AMOUT-Select Data
0
0
15
--
R/W;R
05-00
371 AMOUT-Full-Scale Data Range
0
0
65535
--
FR/W
05-01
372 AMOUT-Test Data( 0~100% Full scale)
0.0
0.0
100.0
%
RAM
05-02
373 AMOUT-100% Full Scale adjustment
0.0
0.0
100.0
%
FR/W
05-03
374 AMOUT-75% adjustment
0.0
0.0
100.0
%
FR/W
05-04
375 AMOUT-50% scale adjustment
0.0
0.0
100.0
%
FR/W
05-05
376 AMOUT-25% scale adjustment
0.0
0.0
100.0
%
FR/W
05-06
377 AMOUT-12.5% scale adjustment
0.0
0.0
100.0
%
FR/W
05-07
Encoder Sensor Group <Refer to Chapter-10.6>
No.
Name
Default
Min.
Max.
Unit
Type
GXX-XX
188 ENCODER DIRECTION
0
0
1
--
FR/W;R 07-00
189 ENCODER PPR
256
256 60000
--
FR/W;R 07-01
190 ENCODER A/B/Z Status
0
0
7
--
M
07-04
191 ENCODER COUNTER
0
0
65535
--
M
07-05
192 ENCODER DATA FILTER BUFFER
6
0
6
FR/W;R 07-03
193 ENCODER CHECK TIME
0
0
30000
ms
R/W
07-08
194 ENCODER TYPE
0
0
2
--
FR/W;R
354 Actual Counts Per Revolution
0
0
65535
Cks
M
Содержание IRIS-IMSV
Страница 1: ...IRIS IMSV DRIVER USER MANUAL Version V5 03 ...
Страница 95: ...16 CE Certificate 16 1 EMC Certificate www jps com tw 94 ...
Страница 96: ...16 2 LVD Certificate www jps com tw 95 ...