www.jps.com.tw
32
THERMISTOR adjust Group <Refer to Chapter-10.12>
No.
Name
Default
Min.
Max.
Unit
Type
GXX-XX
140 Heat sink temperature ( degC)
0
0
250
degC
M
83-00
150 OVER-Temperature Protect LEVEL
80
50
100
degree R/W
83-01
FAN adjust Group <Refer to Chapter-10.13>
No.
Name
Default
Min.
Max.
Unit
Type
GXX-XX
146 FAN control type
0
0
1
--
R/W
84-00
148 FAN measure Speed
0
0
65535
rpm
M
84-02
149 FAN Speed Warning/Trip Level
2000
0
30000
rpm
R/W
84-03
9.2 Monitor Type Parameters’ Address
The table showed below list the Monitor type parameters, and there address. User can read it by communication.
Name
Unit
Address (Pr.)
Driver’s output voltage
V
013
Motor’s actual speed
rpm
019
Driver’s output frequency
Hz
030
Alarm message
--
035
Driver’s output current
rms(Amp)
213
9.3Parameter’s Type
The table showed below describing the different type of all the parameter of this manual:
Type
Description
R/W
The parameter is Readable and Writable, and can be stored in EAROM.
All this type parameters can be initialized by the Pr.369 function.
FR/W
The parameter is Readable and Writable, and can be stored in EAROM.
This type of parameter is specially set by Factory and not for user normally usage.
This type of parameter only can be modified by authorized person.
RAM
The parameter is Readable and Writable, but it uses the RAM to temporally store the
change of parameter. After power on or reset it will be recover to be default value.
M
The parameter is Monitor type. Only readable and no effect for writing this parameter.
F
Factory set parameter, and should not be changed.
R
To indicate that any change of this type of parameter have to Reset the driver to enable
the change.