www.jps.com.tw
28
XY Pulse Tracking Group <Refer to Chapter-14.4>
No.
Name
Default
Min.
Max.
Unit
Type
GXX-XX
396 Servo position gain
0
0
60000 Rpm/rev
R/W
398 X/Y Pulse Counter
0000
0000
FFFF
Cks
M
399 X/Y Input DIRECTION
0
0
1
--
R/W
450 X/Y MUL1 Setting-Value(ROM)
1000
0
65535
--
R/W
451 X/Y DIV1(ROM)
1000
0
65535
--
R/W
452 X/Y Commad Type
0
0
1
--
R/W
453 X/Y Pcmd Sampling time
50
10
1000
--
R/W
454 X/Y Pcmd Feed forward Gain
0
0
100
%
R/W
455 X/Y Input Status
0
0
65535
--
M
IMSV Motor Group <Refer to Chapter-10.7>
No.
Name
Default Min.
Max.
Unit
Type
GXX-XX
116 Motor Pole No
8
2
128
FR/W;R
10-02
198 Motor Ke(Back Emf constant)
0
0
10000 Volts/krpm
202 No-Load Speed (=Base or Synchrnous Speed)
1800
0
30000
rpm
R/W
203 Full-Load SLIP-RPM
60
0
1000
rpm
R/W
210 Full Load Current(?% of AMP-Rating-Current)
50
0
200
%
FR/W
10-00
211 Filed Current(?% of Full-Load-Current)
30
0
200
%
FR/W
10-01
215 Electronic Over-Load Thermal Relay Time
3
0
120
sec
R/W
10-04
216 RESISTANCE(between V&W, U phase open)
1.000
0.00 60.00
Ohm
FR/W
10-05
217 INDUCTANCE(between V&W, U phase open)
1.00
0.00 60.00
mH
FR/W
10-06
IMSV Multi-Speed Setting Group <Refer to Chapter-10.9>
No.
Name
Default
Min.
Max.
Unit
Type
GXX-XX
010 JOG Rpm
60
0
30000
rpm
R/W
119 Actual RPM Set Command
0
-30000 30000
rpm
M
16-10
120 Speed Set0
0
0
30000
rpm
R/W
16-00
121 Speed Set1
0
0
30000
rpm
R/W
16-01
122 Speed Set2
0
0
30000
rpm
R/W
16-02
123 Speed Set3
0
0
30000
rpm
R/W
16-03
124 Speed Set4
0
0
30000
rpm
R/W
16-04
125 Speed Set5
0
0
30000
rpm
R/W
16-05
126 Speed Set6
0
0
30000
rpm
R/W
16-06
127 Speed Set7
0
0
30000
rpm
R/W
16-07
128 Maximum RPM Limit
3000
0
30000
rpm
FR/W
16-08
278 Select Speed Source when SWx=000
0
0
19
-
R/W;R
16-09
Содержание IRIS-IMSV