13.3.6 Timer Function (Auto On/Off Mode)
Example 3: Auto On/Off Mode
TIMER A
DIx(60)
DOx(105)
DOx(104)
Pr.249 = 2:
Auto On/Off Mode
TIMER B
DIx(61)
DOx(107)
DOx(106)
Pr.252 = 2: Auto On/Off Mode
DIx(60)
T1
DOx(105)
DOx(104)
T2
T1
T1
T2
DIx(61)
T1
DOx(107)
DOx(106)
T2
T1
T1
T2
When DIx(60) is ON, DOx(104) output ON/OFF
toggled; T1 determine the ON timing, T2 determine
the OFF timing. When DIx(60) becomes OFF,
DOx(104) becomes OFF immediately.
DOx(105) is opposite to DOx(104).
When DIx(61) is ON, DOx(106) output ON/OFF
toggled; T1 determine the ON timing, T2 determine
the OFF timing. When DIx(61) becomes OFF,
DOx(106) becomes OFF immediately.
DOx(107) is opposite to DOx(106).
www.jps.com.tw
72
Содержание IRIS-IMSV
Страница 1: ...IRIS IMSV DRIVER USER MANUAL Version V5 03 ...
Страница 95: ...16 CE Certificate 16 1 EMC Certificate www jps com tw 94 ...