www.jps.com.tw
76
13.5.2 Speed Up/Down Counter Digital-Input
z
DIx _ Select
Æ
90,Up/Down Buffer Clear to Zero
If input is active, clear the Speed Up / Down counter register to be 0 when be active.
z
DIx _ Select
Æ
91,Up/Down Buffer Trig. INC
If the input is active, increase the Speed Up / Down Counter (Pr.106) when be active.
z
DIx _ Select
Æ
92,Up/Down Buffer Trig. DEC
If the input is active, Decrease the Speed Up / Down Counter (Pr.106) when be active.
z
DIx _ Select
Æ
93,Up/Down Buffer Level-INC
Increase the Speed Up / Down Counter by a preset value in Pr.107 every second.
z
DIx _ Select
Æ
94,Up/Down Buffer Level- DEC
Decrease the Speed Up / Down Counter by a preset value in Pr.107 every second.
z
DIx _ Select
Æ
95,Up/Down Buffer "SAVE Buffer to Pr.105"
Save Speed Up / Down Counter value into Pr.105.
13.5.3 Speed Up/Down Counter Digital-Ouput