※ If Pr.086 select 2:
Use AI1 input as torque limit, and motor will run in the direction of AI1 input with the limit of max speed.
+Torque
+rpm
Q-Ⅰ
Q-Ⅱ
Q-Ⅲ
Q-Ⅳ
Forward
Forward
-rpm
-Torque
Reverse
Reverse
Motor
Generator
Generator
Motor
+Pr.128
-Pr.128
Varied by AI1
Varied by AI1
※ If Pr.086 select 3
The torque is set by AI1 x (Pr.087 Torque Limit-quadrant I).
+Torque
+rpm
Q-Ⅰ
Q-Ⅱ
Q-Ⅲ
Q-Ⅳ
Forward
Forward
-rpm
-Torque
Reverse
Reverse
Motor
Generator
Generator
Motor
+Pr.128
-Pr.128
+Pr.087
-Pr.087
Varied by AI1
Varied by AI1
※ If Pr.086 select 9
Torque-limit source=AI2,similar Pr.086 = 1。
www.jps.com.tw
48
Содержание IRIS-IMSV
Страница 1: ...IRIS IMSV DRIVER USER MANUAL Version V5 03 ...
Страница 95: ...16 CE Certificate 16 1 EMC Certificate www jps com tw 94 ...
Страница 96: ...16 2 LVD Certificate www jps com tw 95 ...