www.jps.com.tw
63
12. Digital Output Function
function
Function Description
Version
Chapter
0
Always OFF
1
Always ON
2
In Running
3
Over Load Pre-Alarm
4
Alarm
5
No Alarm
6
Forward Run and Speed >= Pr.206 (speed compared value).
7
Reverse Run and Speed >= Pr.206 (speed compared value).
9
SPZ (Speed Zero), Speed <= Pr.206.
10
NSPZ (Not Speed Zero), Speed > Pr.206.
13.4
11
Fan Speed < Pr.149
12
SPA: Speed Arrive (Pr.19: Actual speed – Speed Cmd) <Pr.208
C514
13
SPNA: Speed Not Arrive (Pr.19: Actual speed – Speed Cmd )> = Pr.208
C514
14
SPO (Speed Over compared value), Speed >= (Pr.207+Pr.208)
15
SPU (Speed Under compared value), Speed<= (Pr.207-Pr.208)
16
SPE (Speed Equal), the different between Speed and Pr.207 < Pr.208.
13.4
17
INDEX (5ms PGC)
20
INDEX (0±5 degree)
27
Pulse_Frequency-1 > COMPARE-Set1
28
Pulse_Frequency-1 > COMPARE-Set2
29
Pulse_Frequency-1 > COMPARE-Set3
31
Pulse-Counter-1 > COMPARE-Set1
32
Pulse-Counter-1 > COMPARE-Set2
33
Pulse-Counter-1 > COMPARE-Set3
13.1
80
Flip-Flop(1) Output.
81
Flip-Flop (2) Output.
82
Flip-Flop (1) Reverse Output.
83
Flip-Flop (2) Reverse Output.
13.2
85
Over Torque Warning
88
ACCing
89
DECing
97
ABS(AI2 Command Value ) > AI2 Compare Set Value
98
ABS(AI1 Command Value ) > AI1 Compare Set Value
104
Timer A output “Q”
105
Timer A output “/Q”.
106
Timer B output “Q”
107
Timer B output “/Q”.
13.3
Содержание IRIS-IMSV
Страница 1: ...IRIS IMSV DRIVER USER MANUAL Version V5 03 ...
Страница 95: ...16 CE Certificate 16 1 EMC Certificate www jps com tw 94 ...
Страница 96: ...16 2 LVD Certificate www jps com tw 95 ...