5.3 Brake Resistor Terminals
!
NOTE: This driver contains braking discharge circuits. The terminals have icon
are used to
connect external resistor to discharge the re-generating energy when in braking condition.
Refer to the list below when choosing resistor for braking discharge. The wattage of resistor can be increased
for heavier re-generating energy or higher discharge duty.
Model
Resistance(ohm)
Wattage (W)
2R2
400
40
2R3P5
300
60
2R5
200
80
2R7
100
150
2R11
60
250
2R17
40
300
2R24
30
500
2R33
20
600
2R46
15
1000
2R61
10
1500
2R90
10
2000
4R5P5
250
250
4R8P5
150
300
4R12
100
500
4R17
75
750
4R23
50
1000
4R31
40
1500
4R45
40
2000
The discharge duty is 10 %