4. After entering a 5 digit template programming value, the first telephone number is displayed.
Enter the monitoring station telephone number after the “D.” Press [#] to complete the entry.
5. After programming the first telephone number, enter a system account code.
• The system account code can be any 4 or 6-digit combination of numbers (0-9) and letters (A-
F).
• To enter letters A through F, press [*] then the numbers 1 through 6 for the letter A through
F respectively. Press [*] again to revert back to decimal entry. E.g., to enter “1234FF” press
[1234*66].
for additional details. When the system account code programming is
completed, enter a partition 1 account code using the same method as the system account code.
1. After programming the partition 1 account code, the downloading access code is displayed.
Enter the new downloading access code or press [#] to proceed to the next step. The
downloading access code must changed from its default value.
2. The next value is a 3 digit partition 1 entry delay time. Press [>][>][>] to accept the default
time of 30 seconds (030) or enter an entry delay between 001 and 255. E.g., Press 020 for a
delay of 20 seconds. for additional details. The CP-01 models of the Neo panel will not accept
a value less than 30 seconds.
3. The next value is a 3 digit partition 1 exit delay time. Press [>][>][>] to accept the default time
of 120 seconds or enter an exit delay between 001 and 255. E.g., press 030 for a delay of 30
seconds. for additional details. The CP-01 models of the Neo panel will not accept a value less
than 45 seconds.
4. After programming the exit delay, enter a 4, 6 or 8-digit installer code, depending on the
[006] Installer Defined Access Codes
details.
5. Template Programming will automatically exit after the installer's code has been
programmed.
Note:
EN50131-1 compliant systems using 1000 access codes shall set the access code to
8 digits (section [041], option 02).
DLS Programming
DLS programming involves downloading custom programming using DLS software and a
computer. This can be done locally or by remote.
Note:
For UL listed systems an installer must be on the premises.
Local Programming With PC-Link
Follow the steps below in the sequence indicated to set up local programming using DLS:
1. Connect AC Wiring.
In a new installation, the backup battery requires 24 Hrs. charging. AC Power is
required for PC-Link Programming until the battery is charged.
2. Plug the PC-Link header into the alarm controller. A DLS session is initiated on the DLS
computer.
3. When the session is complete, remove the PC-Link cable from the alarm controller.
4. Complete the installation.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
74