Month
Valid entries are 001-012 (January to December).
Week
Valid entries are 000-005.
Enter “000” to program a specific date (1-31) in the Day field. Enter 001-005 to program the specific
week of the month. 005 is the last week of the month.
Day
1-31 (if 000 is programmed in the Week field). 0-6 (Sunday to Saturday) if 001-005 is programmed in
the Week field.
Hour
Valid entries are 00-23 hours. This is the time of day to advance or turn the clock back.
Increment
Valid entries are 1 or 2 hours. This is the number of hours to advance or turn the clock back.
Access Codes
This section is used by installers to program the installer code, the master code and the
maintenance code. For information on programming other access codes,
[006] Installer Defined Access Codes
This is the base menu used by installers to program the installer code [001], the master code [002]
and the maintenance code [003]. See below for details.
[001] – Installer Code
This code is used by the installer to gain access to Installer Programming [*][8]. Users with this
access code have access to all levels of system programming.
Note:
For EN50131-1 approved installations the installer code cannot change the master code
or any other level 3 codes.
[002] – Master Code
This code is used by the master user, a person designated to perform operational tasks beyond
those of the standard user. The master code provides access to functionality in the [*][5] and [*][6]
menus.
[003] – Maintenance Code
This code is usually assigned temporarily to maintenance personnel who must deactivate the alarm
to enter the premises. The maintenance code can arm and disarm the system, but does not grant
access to any other functionality.
[005] – Code Version
A programmable 3 'digit' pin is required to calculate the 5 'digit' remote reset code. The range of
the pin is 000-255 in
decimal. The default value of the pin code is 000.
[007] - [008] PGM Configuration
About this task:
This section describes how to set up and configure programmable outputs.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual