Casual Users
The installer should caution the user not to give system information (e.g., codes, bypass methods,
etc.) to casual users (e.g., service people) and to only give out One-Time Use codes.
User Information
The installer should advise the user and note in the User’s Manual:
• Service organization name and telephone number
• The programmed exit and entry time
• Instructions to test system weekly
• Note that the installer code cannot arm or disarm the system
Note:
For UL Residential Fire applications compliant with UL985 6th edition, the following
guidelines shall be respected when the equipment is used as a combination alarm system for
fire and burglary protection:
• Fire alarm detection devices shall not be powered from the same AUX output (control
panel, zone expander, power supply) as burglary alarm initiating devices.
• Power supply wiring for Fire Alarm Detection devices (Smoke Detectors, CO Detectors)
shall be connected to the control panel AUX output (located on the main control panel
board assembly).
• Power supply wiring for Burglary Alarm Initiating devices (Motion detectors, magnetic
contacts, glass break detectors, etc.) shall be connected to the compatible Power
Supply Modules AUX outputs (located on the power supply module board assembly e.g.
HSM2300, HSM2204) or Expander Module AUX outputs(located on the expander module
board assembly, for example, HSM2108, HSM2208.)
For fire and CO applications, RM-1 (C) or RM-2 power loop supervision relay shall be connected to
Aux Power Output to report wiring faults if it is used for powering fire/CO devices.
Aux Loading and Battery Selection
HS2128/
HS2064/
HS2032/
HS2016-4
Board current
draw 85mA
UL Residential
Burg
ULC
Residential
Burg
UL Commercial
Burg
UL Resi Fire
UL Home
Health Care
ULC Resi Fire
ULC Com Burg
ULC Fire
Monitoring
EN50131
Grade 2/Class
II
Max AUX
(NSC) current
loading
0.7A
0.7A
0.5A*
0.5A
0.5A480mA
Max BELL
(Alarm)
current
loading
0.7A
0.7A
0.7A
0.7A (no
local alarm
notification
allowed,
only remote
transmission
to SRC)
0.7A
265