• [013] Opt [1] for normally closed or EOL; Opt [2] for SEOL or DEOL
• [201 - 208] partition assignment.
Observe the following guidelines when wiring zones:
• For UL listed installations use SEOL or DEOL only
• Minimum 22 AWG wire, maximum 18 AWG
• Do not use shielded wire
• Do not exceed 100 Ω wire resistance. Refer to the following table:
Table 6: Burglary Zone Wiring Chart
Wire Gauge
Maximum Length to EOL Resistor (ft/meters)
22
3000 / 914
20
4900 / 1493
19
6200 / 1889
18
7800 / 2377
Figures are based on maximum wiring resistance of 100 Ω.
Normally Closed
Connect hardwired devices to any Z terminal and any Com terminal. Wire normally closed devices in
series.
Note:
For UL Installations, do not use normally closed loops.
Figure 9: Normally Closed
The following table shows zone status under certain conditions for NC Loops:
Table 7: NC Loop Status
Loop Resistance
Loop Status
0Ω (shorted wire, loop shorted)
Secure
Infinite (broken wire, loop open)
Violated
Single End-of-Line (SEOL) Resistor
When SEOL resistors are installed at the end of a zone loop, the alarm panel detects if the circuit
is secure, open, or shorted. The SEOL resistor must be installed at the end of the loop for proper
supervision.
To enable SEOL supervision, program section [013], options [1] and [2] to OFF.
Note:
This option should be selected if either normally closed or normally open detection
devices or contacts are used.