3 - Not Used
4 - R Button
ON: When the panel goes off hook to communicate, it performs a dial tone check. If no dialtone is
detected, the panel will wait 20 seconds and perform another 5 second dial tone search. If dial tone
is still not present, the panel force dials if programmed to do so. This entire sequence counts as one
dialing attempt.
OFF: If no dial tone is present, the panel does not attempt to switch to a second phone line.
5 - Audible Bus Fault
ON: All module supervisory trouble conditions activate the siren.
OFF: Only zone expander supervisory trouble conditions while armed activate the siren.
6 - Duress Codes
ON: The duress code attribute can be enabled/disabled from the [*][5] menu. For UK BS8243
installations the default is off.
OFF: The duress code attribute is not programmable from the [*][5] menu.
7 - Temperature in Celsius
ON: Temperature is displayed in Celsius on LCD keypads.
OFF: Temperature is displayed in Fahrenheit on LCD keypads.
8 - Reset After Zone Activation
ON: Only a police code\sequential detection alarm requires a remote reset once the partition has
been disarmed.
OFF: Any burglary alarm requires a remote reset once the partition has been disarmed.
[020] System Option 8
1 – Access Code Entry During Entry Delay
ON: During entry delay the alarm system can only be disarmed using a keyswitch or proximity tag.
When the siren is active an access code can still be used to disarm the system.
OFF: An access code can be used to disarm the system during entry delay.
2 - EU Entry Procedure
ON: If an alarm occurs on a zone when entry delay is not active, the siren activates and the alarm is
communicated immediately, depending on the zone type tripped.
When entry delay is active, all burglary type alarms activate the siren, but communication of the
alarm is delayed by 30 seconds. When entry delay expires, the alarm is not communicated unless
the siren has been active for at least 30 seconds.
Police code is not generated as a result of alarms triggered during entry delay, although the
Burglary Verification Timer starts after entry delay and the 30-second communication delay expire.
This feature is only active when the partition is armed.
OFF: Burglary alarms that occur during entry delay activate the siren and are communicated
immediately. Two exceptions are if the bell delay timer is programmed and if transmission delay is
enabled for the zone in alarm. In both cases, the alarm follows the timer.
3 - [*][8] Access While Armed
ON: This option ensures [*][8] installer programming is accessible from a keypad on a disarmed
partition while other partitions on the system are still armed.
119
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual