OFF: The keypad ready LED will turn off when keypad blanking is active.
55 - PGM Blanking
This feature is meant to be used in conjunction with the keypad blanking while armed feature.
ON:This feature is necessary to comply with EN50131-1:2006.
When the system enters blanking mode, any PGMs programmed as Armed Status, Ready Status,
Away Armed Status, or Stay Armed Status will de-activate. If blanking is cleared by pressing a key,
or entering an access code depending on how the panel is configured, these PGMs must re-activate
if they would have normally been ON if blanking was disabled.
OFF: When the system enters blanking mode, any PGMs programmed as Armed Status, Ready
Status, Away Armed Status, Stay Armed Status) operate normally.
6 - Armed Display
ON: The keypad armed LED will continue to show Armed status while keypad blanking is active.
OFF: The keypad armed LED will turn off when keypad blanking is active.
7 - Open Zones Cancels Arming
ON: The system cannot be armed while zones are open unless the zones are bypassed using [*][1].
In order to bypass open zones, the bypass attribute needs to be enabled for the zone.
OFF: Open zones do not prevent arming.
8 - Audible Exit Delay for Stay Arming
ON: When the system is armed in Stay mode the exit delay is sounded by 1 beep every 3 seconds.
OFF: When the system is armed in Stay mode the exit delay is silent.
[022] System Option 10
1 - [F] Key Option
ON: When the [F] key is pressed, acknowledge beeps are only emitted from the keypad. The siren
does not sound.
OFF: [F] key acknowledgment beeps are emitted from the keypad and the siren.
2 - Not Used
3 - Not Used
4 - Transmission Counter in Hours
ON: The alarm system sends a test transmission after the programmed number of hours in the test
transmission cycle (Section [377], Option 003).
OFF: The alarm system sends a test transmission after the programmed number of days.
5 - Away to Stay Toggle
ON: The alarm system cannot be switched from Away to Stay mode by pressing the [Stay] function
key.
OFF: The alarm system can be switched from Away to Stay mode by pressing the [Stay] function
key.
6 - 2-Way Audio Disconnect
ON: The system does not disconnect the 2-way audio session if a new event needs to be
communicated.
Note:
This option applies to new alarm events only. All non-alarm events (except Fire Troubles)
are communicated after the 2-Way session has ended.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
122