11 - Duress Alarm
ON: activates on duress alarm.
OFF: does not activate on duress alarm.
12 - Emergency Alarm
ON: activates on emergency alarm.
OFF: does not activate on emergency alarm.
13 - Fire Supervisory
ON: activates on fire supervisory alarm.
OFF: does not activate on fire supervisory alarm.
14 - Fire Trouble
ON: activates on fire trouble condition.
OFF: does not activate on fire trouble condition.
15 – CO Alarm
ON: activates on CO alarm.
OFF: does not activate on CO alarm.
157 - System Tamper
01 - True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
09 - System/Module Tampers
ON: activates when any module tamper condition occurs.
OFF: does not activate when any module tamper condition occurs.
10 - Zone Tampers
ON: activates when any zone tamper condition occurs.
OFF: does not activate when zone tamper conditions occur.
161 - DC Trouble
01 - True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
02 - PGM Timer
ON: output remains active until an access code is entered or certain criteria have been met,
depending on the PGM type.
OFF: output remains active until the PGM output timer expires.
09 - Battery Low
ON: activates when a low battery trouble occurs.
OFF: does not activate when a low battery trouble occurs.
10 - Battery Absent
ON: activates when a battery absent trouble occurs.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual