ULC Commercial Burglary
The following wireless PowerG devices models are ULC listed under ULC-S304 requirements for use
in Commercial Burg applications rated for Security Level III.
PG9914
PG9929
PG9944
PG9984
PG9905
PG9934P
PG9945
PG9984P
PG9920
PG9935
PG9949
PG9985
PG9922
PG9938
PG9974
PG9994
PG9924
PG9939
PG9974P
The wireless supervision window shall be set to 4h for such applications and the tamper detection
for removal from mounting location shall be enabled.
UL Central Station and Police Connect with Standard or Encrypted Line
Security Service
• The installation must use the Models TL2803G(R)E IP/3G Interface, 3G2080(R)E 3G Interface
or TL280(R)E IP Interface, which communicates over Cellular Data Network or an Ethernet
network 10/100BaseT to the compatible Sur-Gard System I/II/III/IV receiver
• Polling time shall be 200 seconds and compromise detection time shall be 6 min.
• For Encrypted line security applications, the Models TL2803G(R)E IP/3G Interface, 3G2080(R)E
3G Interface or TL280(R)E IP Interface shall have the Encryption Key enabled (AES128 bit
encryption algorithm is validated under NIST Certificate No.2645
• Wireless Supervision window shall be enabled (refer to Wireless Programming, sections
[804]>[802])
UL Local, Central Station, Police Connect with No Line Security Service
• The installation shall use a Bell UL Listed for Mercantile local alarms (e.g., Amseco Model
MBL10B bell with Model AB-12 bell housing). Connections from the control unit to the bell shall
be made in conduit. (Optional for central Station)
• The bell timeout shall be programmed for 15 minutes minimum
• At least one system remote keypad with tamper switch shall be employed
• The integral DACT shall be enabled and shall be programmed to provide a low battery
transmission
• The control panel shall be in a separately listed CMC-1 or PC4050CA attack resistant enclosure
• The maximum entry delay time shall not exceed 45s as a result of the attack test. The
maximum exit delay time shall not exceed 60 s.
• A tamper switch shall be used to protect the enclosure cover of the control unit, and shall also
be used on the keypad rear to detect removal from the wall.
• 24 h check in transmission shall be enabled
• Open/Closing acknowledgement enabled (Not Police Station).
• The Installation shall use the internal dialer (DACT) alone or in conjunction with Models
TL2803G(R)E IP/3G Interface, 3G2080(R)E 3G Interface or TL280(R)E IP Interface, which
communicates over Cellular Data Network or an Ethernet network 10/100BaseT to the
compatible Sur-Gard System I/II/III/IV receiver