• User Labels
System and module programming is not affected.
Hardware Reset Main Control Panel
Perform the following to restore the main control panel to default settings:
1. Power down the system.
2. Remove all wires between Zone 1 and PGM 1 on the alarm controller.
3. Connect a short between Zone 1 and PGM.
4. Power up the system (AC only) for 60 seconds.
5. Power down the system and remove the short.
6. Power up the system again. Factory defaults are restored.
Hardware default is logged to the event buffer.
Note:
Hardware default is not available when installers lockout is enabled
Alternate Communicator Setup
The alternate communicator is an optional wireless or ethernet communications device that can be
used as a backup to the PSTN connection or as a primary means of communication between the
alarm panel and the central monitoring station. The alternate communicator communicates via 3G
(HSPA) or Ethernet.
The following configuration steps are required to set up the alternate communicator:
• Install the alternate communicator and wire it to the alarm panel (use PCLINK_2 header)
• Enroll the alternate cellular communicator with Connect 24
• Set the communication path: [300]
• Enable the alternate communicator: [382] option 5
• Enable event reporting: [307]/[308]
• Program communication delay timer: [377]
• Program DLS access: [401] option 07
Refer to the 3G2080(R)E/ TL2803G(R)E/ TL280(R)E installation manual for details.
Real Time Clock
This feature synchronizes the alarm panel time and date with that of the alternate communicator,
provided real time clock support is available. Time and date are updated at 4:05 PM or when the
system time is lost. This feature is enabled/disabled in Installer Programming section [024] option
5.
Communication Paths
The path of communication between the alarm panel and the central station must be established
through either the alarm panel’s on-board Public Switched Telephone Network (PSTN) connection
or through the alternate communicator (cellular or Ethernet) if equipped.
Paths to four receivers can be programmed in Installer Programming section [300] options 001 -
004.
For more information,
[300] Panel/Receiver Communication Paths
.