The default attributes of an access code are the same as the code used to enter [*][5], whether a
new code is programmed or an existing one is edited. The available attributes are as follows:
• Supervisor
• Duress code
• Zone bypassing
• Remote access
• Bell squawk
• One time use code
1 - Supervisor
Converts standard user into supervisor user. See
2 - Duress Code
Converts standard user code into duress code. See
3 - Zone Bypassing
Users with this attribute can bypass zones. Section [023] option 4, Access code required for [*][1],
must be on to use this attribute.
4 - Remote Access
Users with this attribute can access the alarm system remotely via SMS.
7 - Bell Squawk
When this option is assigned, the main bell squawks when the alarm system is away armed. For
example, use the arm/disarm bell squawk attribute to have wireless key access codes squawk the
bell, while other codes are silent. To do this, enable this attribute on all access codes associated
with wireless keys. This option is off by default for all access codes.
Note:
One squawk indicates arming completed; two squawks indicates disarming completed.
Note:
This feature is independent of the system option “Bell Squawk on Away Arming.” See
The master code's attributes cannot be changed from default. The bell squawk is off at default.
8 - One Time Use Code
Converts standard user code into one time use code.
for details. Do not apply
this code to users with wireless keys assigned.
Using an LCD keypad:
1. Press [*][5][Master Code].
2. Use the scroll keys to choose a user (02-1000) then press [*] to select.
3. Scroll to “Press [*] for User Options” then press [*] to select.
4. Scroll to a user attribute and press [*] to toggle it on or off.
Using an LED/ICON keypad:
1. Press [*][5][Master Code].
2. Enter the access code to edit. Press [5] for attribute programming.
3. Press the keypad number key corresponding to an attribute to toggle it on or off.
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual
64