7 – 1 Hour DLS Window
☐
8 – FTC Audible Bell
[040] User Authentication
Description on
☑
1 – User Code or Prox. Tag
☐
2 – User Code and Prox. Tag
[041] Access Code Digits
Description on
☑
00 – 4-Digit Access Codes
☐
01 – 6-Digit Access Codes
☐
02 – 8-Digit Access Codes
[042] Event Verification
Description on
01 – Burglary Verified Counter (Default: 002):
02 – Holdup Counter (Default: 002):
03 – Burglary Verification
Selection:
001 – Police Code (Default)
002 – Cross Zoning
003 – Sequential Detection
Auto-Arm / Disarm
[151] Partition 1 Auto-Arm/Disarm
Description on
[151]-[158] Partition Auto-Arm/Disarm
001 – Partition 1 Auto-Arming
Times:
24-Hour:
(4-digit HH:MM)
Sunday:
Thursday:
Default: 9999
Monday:
Friday:
Tuesday:
Saturday:
Wednesday:
002 – Partition 1 Auto-Disarm
Times:
24-Hour:
(4-digit HH:MM)
Sunday:
Thursday:
Default: 9999
Monday:
Friday:
Tuesday:
Saturday:
Wednesday:
003 – Partition 1 Auto-
Disarming Holiday Schedule:
Holiday 1: o On
☑
Off
(3-digit decimal)
Holiday 2: o On
☑
Off
Holiday 3: o On
☑
Off
Holiday 4: o On
☑
Off
004 – Partition 1 Auto-Arming Pre-Alert (Default: 004):
005 – Partition 1 Auto-Arming Postpone Timer (Default: 000):
006 – Partition 1 No Activity Arming Timer (Default: 000):