[202] Open/Close Events 2
1 - Automatic Closing
This reporting code is transmitted when a partition is automatically armed or schedule armed and
uses the Opening call direction group.
2 - Automatic Disarm
This reporting code is transmitted when a partition is automatically disarmed when a scheduled
time of day is reached.
3 - Auto Arm Cancellation/Postpone
This reporting code is transmitted when the automatic arm sequence is canceled during a pre-alert
and uses the Opening and Closing call direction group.
[211] Miscellaneous Open/Close Events
1/2 – Late to Close/Open
This reporting code is transmitted when a partition is not disarmed before the automatic disarm
time, when the late to open option, ([*][6], option 9) is enabled. The Opening and Closing call
direction group is used for this reporting code.
5 - Exit Fault
This reporting code is transmitted when an exit error occurs and entry delay expires before the
system is disarmed. The Alarms and Restores call direction group is used for this reporting code.
If the delay zone that caused the exit error has cross zoning enabled, the exit fault and zone
alarm transmits if a second zone is not tripped. The local alarm sequence follows cross zoning
rules. The exit error is transmitted with the zone alarm that caused the fault, even if that zone has
transmission delay enabled.
[221] Bypass Events
1/2 – Automatic Zone Bypass/Unbypass
This reporting code is transmitted when a zone is automatically bypassed/unbypassed and uses the
Opening and Closing call direction group.
Note:
Must be enabled in UK.
03 - Partial Closing
This reporting code is transmitted if zones are manually bypassed at the time of arming or force
armed by automatic arming. The Opening and Closing call direction group is used for this reporting
code.
Automatic bypasses caused by stay arming do not cause transmission of this code.
[301] Panel Events 1
1/2 – Panel AC Fail Trouble/Restore
This reporting code is transmitted when the alarm system AC supply fails or has been restored. A
programmable delay applies to both the trouble and the restore. This reporting code is sent to the
System Maintenance call direction group.
133
PowerSeries Neo HS2016/HS2016-4/HS3032/HS2064/HS2064 E/HS2128/HS2129 E Alarm Controller Reference
Manual