OFF: The system disconnects the 2-way audio session if a new event occurs.
7 - Trouble Beeps are Silent
ON: When a trouble is detected on the system, trouble beeps are not sounded at the keypad with
the exception of Fire troubles.
OFF: When a trouble is detected on the system, trouble beeps are sounded at the keypad.
Note:
This option must be OFF for UL Residential Fire applications.
8 - Keyswitch Arms in Away Mode
ON: Keyswitch arming arms the alarm system in away mode.
OFF: Keyswitches only arm the system in away mode if an entry/exit zone is violated during exit
delay.
Note:
Proximity tag arming follows this section.
[023] System Option 11
1 - Ready LED Flashes for Force Arm
ON: If a force arm capable zone is tripped, partition keypads flash the ready LED in the disarmed
state instead of illuminating it steadily. If a non-force arm capable zone is tripped, the ready LED
turns off.
OFF: If a force arm capable zone is tripped, the Ready LED is illuminated steadily. If a non-force arm
capable zone is tripped, the Ready LED turns off.
2 - Not Used
3 - Tamper/Fault Detection
ON: The following trouble conditions, when configured to generate audible alarm conditions, will
contribute to a burglary verification sequence when sequential detection is used. When enabled, a
bell circuit trouble will also generate an audible alarm condition using other sirens that assigned to
the partition.
• TLM trouble
• Bell circuit trouble
• Zone fault
• Module supervisory trouble
• Alternate Communicator fault
• Ethernet Trouble
OFF: Trouble conditions are displayed and processed as standard operation.
Note:
This option applies to the Sequential Detection feature only.
4 - Access Code Required for [*][1]
ON: When using the [*][1] Bypass Zones command, an access code must be input before zones are
bypassed.
OFF: An access code is not required to bypass zones using [*][1].
5 - Access Code Required for [*][2]
ON: When using the [*][2] View Troubles command, an access code must be input before system
troubles can be viewed.
OFF: An access code is not required to view troubles using [*][2].
123